Three issues reported on Windows + one user-requested limit bump:
1. Dashboard CPU/RAM/Network all at 0
handleSystemMetrics read /proc/* exclusively. Replaced with a
platform-split:
- metrics_unix.go (!windows): existing /proc reading code.
- metrics_windows.go: kernel32!GetSystemTimes for CPU
(delta of idle vs kernel+user FILETIMEs) and
kernel32!GlobalMemoryStatusEx for memory. Network left at zero
for now — MIB_IF_ROW2 is too version-sensitive to parse by hand.
handlers_info.go::handleSystemMetrics reduced to one delegating
call.
2. Terminal black screen on Windows
creack/pty/v2 returns "unsupported" on Windows; the v0.7.1 pipe
fallback works but pipes don't carry TTY signals, so cmd/pwsh/wsl
go silent. Implemented native ConPTY:
- terminal_conpty_windows.go: CreatePseudoConsole + STARTUPINFOEX
+ PROC_THREAD_ATTRIBUTE_PSEUDOCONSOLE wiring via
windows.NewProcThreadAttributeList. CreateProcessW launches
child with the PC attached, full ANSI / line discipline /
resize.
- canUseConPTY() probes once at startup (Win10 1809+ check).
- Restructure: terminal_session.go now holds just the interface
+ ptySession + pipeSession structs. terminal_session_unix.go
wires creack/pty. terminal_session_windows.go tries ConPTY
first, falls back to pipeSession.
3. Agent stops after 15 tool calls
MaxToolIterations bumped 15 → 500. Doc comment explains why the
cap exists at all (infinite-loop safety) and that 500 is well
above realistic usage.
- internal/version/version.go: 0.7.5 → 0.7.6
- CHANGELOG.md: v0.7.6 entry covers the three fixes